Point rooflights
Point rooflight
polycarbonate, fixed or vented
Point roof rooflight with multiwall polycarbonate glazing, for natural daylighting. Available fixed or with an opening (vented) segment, manual or electric actuation. Classified to EN 1873:2005.
- Harmonised standard:
- EN 1873:2005
- Product code:
- GUL-SW-PC
Photo: GULAJSKI
Documents & certification
- Harmonised standard
- EN 1873:2005
- Assessment system (AVCP)
- 3
- Declaration of performance
- Świetlik 2/01/2022
- Manufacturer
- GULAJSKI · Świetlik punktowy
- Product code
- GUL-SW-PC
- DTR 17 (04.2025) — Technical and operational documentation / installation instructions
- Świetlik 2/01/2022 — Declaration of performance (EN 1873:2005)
The documents are provided on request, at office@dasitrade.ro.
Request the documentsDescription
GULAJSKI point rooflights with polycarbonate glazing are systemic roof assemblies that, in normal operation, provide natural daylighting through the roof slope. They are installed on flat or low-slope roofs of single-storey buildings, as well as on flat roofs or above stairwells in multi-storey buildings.
They come in two variants: fixed (non-opening) and with a tilting segment with a ventilation function (opening). The glazing is made of multiwall polycarbonate sheets (opal or transparent; optionally with a non-fire-spreading (NRO) fabric interlayer between two sheets).
The base (mounting curb) can be made of galvanised steel, aluminium, PVC or polyester laminate, in straight, sloped or straight-slant variants, with heights from 150 to 750 mm depending on the roof structure.
Applications
- Natural daylighting of single-storey halls and buildings (e.g. industrial, commercial, logistics)
- Flat or low-slope roofs
- Natural ventilation of the spaces below (opening variant)
- Flat roofs or above stairwells in multi-storey buildings
Technical specifications
| Variants | Fixed (non-opening) or with a tilting segment (ventilation) |
|---|---|
| Glazing | Multiwall polycarbonate (opal or transparent); optional non-fire-spreading (NRO) fabric interlayer between two sheets |
| Base | Galvanised steel (min. 1.25 mm) or aluminium (min. 2.0 mm): straight / sloped / straight-slant, 150–750 mm. Also in PVC or polyester laminate (laminate: straight / sloped, 150–500 mm) |
| Base insulation | Mineral wool / polystyrene, min. 40 mm |
| Tilting-segment frame | PVC profiles + aluminium Z-profiles, perimeter seals |
| Hinges | 2–5 stainless steel (opening variant) |
| Actuation (opening variant) | Manual (screw opener with crank, 300 mm stroke) or electric (230 V AC / 24 V DC, standard 300 mm stroke, IP54; optional 500/750 mm, IP33) |
| Use restriction | Opening at wind speeds above 15 m/s is prohibited |
| Installation | By the manufacturer’s teams or authorised/trained units |
Declared performance
| Code | Characteristic | Declared value |
|---|---|---|
| Ap | Air permeability | Ap 2.8/100 |
| — | Watertightness | Pass |
| UL | Resistance to upward loads | UL 600 |
| DL | Resistance to downward loads | DL 1000 |
| — | Impact resistance — small hard body | Pass |
| SB | Impact resistance — large soft body | SB 300 |
| — | Reaction to fireNPD — no performance determined | NPD |
| — | External fire performance | NPD |
Dimensions
Base height: 150–750 mm for steel/aluminium (straight / sloped / straight-slant); 150–500 mm for laminate (straight / sloped). Sizes made to order.